Cell Logic Class II, Type A2 Biosafety Cabinets (BSCs) provide superior personnel, product and environmental protection from hazardous particulates, including agents requiring BSL 1-4 containment. These BSCs are designed to meet the specific needs of cell research. Models feature a modified sash to accommodate a microscope and/or a temperature-controlled work area on the work surface to maintain cell viability.

Designed for versatility, these BSCs exhaust HEPA-filtered air into the laboratory, or into an exhaust system through the optional Ventus II Canopy Connection. When canopy-connected the Logic BSC can be used for applications involving minute quantities of volatile toxic chemicals and trace amounts of radionuclides.

During operation, room air is drawn into the inlet grill of the Logic BSC. The air in the plenum beneath the work surface is a mix of unfiltered room air and the air that has just passed through the work area. This contaminated air is drawn by the ECM blower through the back plenum of the BSC, where approximately 70% is recirculated through the supply HEPA filter and back over the work area, providing an ISO Class 5 work environment. The remaining contaminated air is discharged into the environment after passing through the exhaust high-efficiency HEPA filter.

Mitigating Microbial Risk: Biosafety Cabinet eBook
This ebook will guide you to the answers you need. Start with general guidance, then take a deeper dive into selecting the right biological safety cabinet for your application, laboratory safety tips and other useful subjects.

Click here: Get a quote now

Category:

Code: LC014

Features
Features (All Models)
-Long-life DC Electronically Commutated Motor (ECM)
-Constant Airflow Profile™ (CAP) airflow monitoring system
-BalanceFlow™ plenum provides energy-efficiency and ultra-quiet operation*
-Easy clean top cover that promotes even exhaust airflow from the top cover
-Mag-Zone™ area on interior right side manages storage challenges with Labconco Magnetic Mag-Zone accessories
-Intrinsically-safe negative pressure design
-Fully scannable 99.99+% supply and exhaust HEPA filters. 99.999% efficient ULPA filters or H14 HEPA filters also available
-Logic OS and 5″ interior-mounted, line-of-sight touchscreen information center
-Smart-Start™ System allows user to start up and shut down cabinet functions by raising and lowering the sash
-Night-Smart™ System for idling the blower when the sash is fully closed
-Full operational maintenance and certification logs for detailed record keeping
-Status line for alarm conditions and alerts to warn when filter life diminishes to 20% and 10% before alarming at 0%
-Interval/elapsed timer for experiment monitoring
-UV light timer (on models with UV)
-Password protection for cabinet settings
-8 Languages
-Bright, glare-free LED lighting up to 180 foot-candles (1937 lux). Located outside the contaminated work area
-Curved, stainless steel inlet grille with waterfall design and Reserve-Air™ Secondary Airflow Slots
-Air-Wave™ Entry System at access opening to enhance containment
-Contain-Air™ Negative Pressure Channel at top of sash to enhance containment
-Two electrical outlets. Flush mounted stainless steel cover with dampened hinges
-115V GFCI, double receptacles, maximum amperage draw 5A
-230V, single receptacles, maximum amperage draw 3A
-10° angled, fully closing sash. 1/4″ tempered safety glass with counterbalanced, anti-racking, easy-to-lift mechanism
-Unitized, pressure tested stainless steel interior. Optic White epoxy-coated steel exterior
-Removable towel catch located under work surface
-8″, 10″, or 12″ (20.3, 25.4, or 30.5 cm) working sash height
-22.5″ (57 cm) max. sash opening & 27.0″ (69 cm) viewing height
-Removable, seamless type 304 stainless steel, dished work surface with lift out knobs
-Nominal inflow velocity of 105 fpm (0.53 m/sec)
-Nominal downflow velocity of 55 fpm (0.28 m/sec). 6′ x 12″ sash models nominal downflow velocity of 50 fpm (0.25 m/s)
-Approximately 70% air recirculation
-Noise level <60 dB (4ft 10″ model)
-10′ (3 m) power cord with plug
-Six year warranty

Options
3’, 4’, 5’ and 6’ widths
International electrical configurations
Unassembled, NSF-approved, epoxy-coated steel, non-welded telescoping base stand with leveling feet

Accessory Package
UV lamp (254 nm)
Right-side service fixture with ball-type valve
Right and left-side Vacu-Pass™ Cord & Cable Portal
Ventus II Canopy Connection
Cell Logic Packages
Scope-Ready™ Package consisting of 7.0″ wide x 10.5″ high (18 x 27 cm) sash cutout and Pure-Vu™ Seal with powder-coated steel collar. Stand-Still™ Isolation Platform is required and sold separately.
Temp-Zone™ Package consisting of temperature-controlled work area, 10.5″ wide x 12.0″ deep (27 x 30 cm) located on the left side of the work surface. Water circulator is required (not included). Circulator requirements: minimum flow rate of 0.4-0.5 GPM (1.5-1.9 LPM), typical volume of 6 liters, and temperature of 0-50° C (chiller/heater).
Required Accessories (Not Included)
Supporting base if non-welded stand option is not selected

Compliance
NSF/ANSI Standard 49 listed
NSF/ANSI 49 compliant (Cell Logic models)
ISO Class 5 (Grade A) per ISO 14644-1
UL Standard 61010-1
CAN/CSA 22.2 No. 61010-1
CE/UKCA Mark (230V models)
ADA-compliant